MDC Terminal Server

  • 4 e 8 porte seriali RS232 con isolamento galvanico
  • 10/100 Ethernet
  • Certificato per gli standard medici di sicurezza IEC 60601-1:2003
  • In grado di funzionare come concentratore al posto letto totalmente compatibile per Philips DeviceLink II

  Richiedi preventivo
Aggiungi a Preferiti

Hardware Specifications - IOLAN MDC - RS232 with Galvanic Isolation

 
IOLAN MDC4
IOLAN MDC8
Processor
MPC8349E, 400 Mhz, 750 MIPS
Memory
RAM MB
32
64
Flash MB
16
16
Interface Ports
Number of Serial Ports
4
8
Serial Port Interface
RS232 DTE on RJ45
Sun / Solaris
Yes
Serial Port Speeds *
50bps to 230Kbps with customizable baud rate support
Data Bits *
5,6,7,8, 9-bit protocol support
Parity *
Odd, even, Mark, Space, None
Flow Control *
Hardware, Software, Both, None
Serial Port Protection
Galvanic Isolation - basic insulation of 1500Vac
Recessed ports satisfies UL “Test Finger”
15Kv Electrostatic Discharge Protection ( ESD )
Network
10/100/1000 base TX Ethernet RJ45
Software selectable Ethernet speed 10/100 Auto
Software selectable Half/Full/Auto duplex
Ethernet Isolation
1.5Kv Magnetic Isolation
Power
Power Supply
USA models
IEC320-C13 to NEMA 5-15P line cord
UK models
IEC320-C13 to BS1363 line cord
EU models
IEC320-C13 to CEE 7/7 Schuko
South Africa Models
IEC320-C13 to BS546 line cord
Australia models
IEC320-C13 to AS3112 line cord
Nominal Input Voltage:
110/230v AC
Input Voltage Range:
100-240v AC
AC Input Frequency:
47-63Hz
Current Consumption @ 100v ( Amps )
0.21
0.25
Current Consumption @ 240v ( Amps )
0.13
0.14
Typical Power Consumption ( Watts )
12
15.5
Power Line Protection
Fast transients: 1 KV ( EN61000-4-4 Criteria B )
Surge: 2KV ( EN61000-4-5 common mode),
1KV ( EN61000-4-5 differential and common modes
Indicators
LEDs
Power
Systems Ready
Network Link Activity
Environmental Specifications
Heat Output ( BTU/HR )
40.95
52.9
MTBF( Hours )
130767
125287
Operating Temperature
0C to 55C, 32F to 131F
Storage Temperature
-40C to 85C, -40F to 185F
Humidity
5 to 95% (non condensing) for both storage and operation.
Case
Painted Aluminum
Ingress Protection Rating
IP40
Mounting
Universal mounting plate for mounting on a flat wall or hospital head-wall systems
Product Weight and Dimensions
Dimensions
25.9 x 27.3 x 5.0 cm
Weight
1.4 kg
1.4 kg
Packaging
Shippng Weight
34.5 x 36.5 x 9.6 cm
Shipping Dimensions
2.1 kg
2.1 kg
Regulatory Approvals
Emissions:
FCC Part 15, Subpart B, Class A
CFR47:2003, Chapter 1, Part 15 Subpart B,(USA) Class A
ICES-003,Issue 4, February 2004 (Canada)
EN55022:1998 +A1:2000 + A2:2003 Class A
EN61000-3-2 : 1995, Limits for Harmonic Current Emissions
EN61000-3-3 : 1995, Limits of Voltage Fluctuations and Flicker
Immunity:
EN55024:1998 + A1:2001 + A2:2003
EN61000-4-2: Electrostatic Discharge
EN61000-4-3: RF Electromagnetic Field Modulated
EN61000-4-4: Fast Transients
EN61000-4-5: Surge
EN61000-4-6: RF Continuous Conducted
EN61000-4-8: Power-Frequency Magnetic Field
EN61000-4-11: Voltage Dips and Voltage Interruptions
Safety:
IEC 60950-1 : 2005 (2nd Edition) + A1 : 2009 and
EN 60950-1 : 2006 + A11 : 2009
CAN/CSA-C22.2 No. 60950-1-03 and ANSI/UL 60950-1,
First Edition April 1st 2003 (Recognized Component)
Medical Safety:
EN 980:2003 : Graphical symbols for use in the labeling of medical devices
EN 1041:1998: Information supplied by the manufacturer with medical devices
IEC 60601-1: 3rd Edition, EN60601-1:1990, +,
A1:1993, A2:1995, + A11 :1994, + A12 :1994,
+ A13 :1996: Medical electrical equipment - General requirements for safety
IEC 60601-1-1:2001: Medical Electrical Equipment -
General requirements for safety - Collateral standard
IEC 60601-1-2:2001, EN60601-1-2:2001 Medical electrical equipment - General requirements for safety - Collateral standard - Electromagnetic compatibility - Requirements and tests
UL 60601-1:2003: Medical electrical equipment - General requirements for safety
CSA C22.2-601.1-M90 with S1-94 and B-90 (R2001)
AS/NZS 3200.1.0:1998 Medical electrical equipment -
General requirements for safety
Other:
RoHS - 2002/95/EC Directive
WEEE - 2002/96/EC Directive
CCATS - G052929
ECCN - 5A992A
HTSUS Number: 8471.80.1000
Warranty:
Perle Lifetime Warranty
* Features only apply when using "IOLAN" firmware

IOLAN MDC

IOLAN RJ45 Socket
Function
1
DTR (out)
2
TxD (out)
3
RxD (in)
4
DCD (in)
5
RTS (out)
6
CTS (in)
7
low current output (-12V)
(out) VLL *
8
low current output (+12V)
(out) VHH *
9
GND
10
Shield

* applicable when operating as a plug
compatible Philips DeviceLink controller

» Torna su

 

Terminal Server | Console Server | Device Server | Ethernet IO Device Server | Scheda Seriale | Soluzione per il seriale su Ethernet
Media Converter Ethernet | Soluzioni Ethernet a Fibra | Mappa del sito | Note legali | Informativa sulla privacy | Contatti
Copyright © 2012 Perle. Tutti i diritti riservati

[ Siti internazionali ]