Perle home Perle home Perle home
  • Italiano

    Global - English

    Deutsch

    Français

    Español

  • Contattaci
  • PRODOTTI
  • APPLICAZIONI
  • COME ACQUISTARE
  • ASSISTENZA
  • SU PERLE
  1. Prodotti
  2. Convertitori Seriale a Fibra
  3. RS232/FO 1300 E
  4. Print Friendly Version of this page Print Get a PDF version of this webpage PDF

Convertitore Seriale a Fibra PSI-MOS-RS232/FO 1300 E

Connettere i dispositivi RS232 al cavo in fibra ottica

Convertitore Seriale a Fibra PSI-MOS-RS232/FO 1300 E

Convertitore Seriale a Fibra PSI-MOS-RS232/FO 1300 E

Convertitore Seriale a Fibra PSI-MOS-RS232/FO 1300 E
  • Estendere i dati seriali fino a 45 km
  • Immune a EMI, RFI e sovratensioni dei transitori
  • Configurazione punto a punto e a stella
  • Connettori in fibra di tipo SC
  • Connettore DB9 maschio DTE/DCE RS-232 configurabile
Richiedi preventivo
  • Panoramica
  • Hardware
  • Diagrammi
  • Documentazione
  • Come Acquistare

Il converter PSI-MOS-RS232/FO 1300 E da seriale a fibra consente di collegare in modo trasparente i dispositivi RS232 a un cavo in fibra ottica. Trasmettendo i dati RS232 sulla fibra ottica, questi media converter costituiscono un percorso economico per raggiungere i dispositivi seriali.

Trasmissione dati seriali a lunga distanza sulla fibra

La trasmissione seriale di RS232 è limitata a 20 Kbps su una distanza di soli 15 metri. Con l’utilizzo del converter FO 1300 da seriale a fibra è possibile prolungare la trasmissione di dati seriale fino a 27 km su fibra multimodo o 45 km su una fibra a modalità singola. Il risultato è la possibilità di comunicazione di due dispositivi asincroni seriali, situati a chilometri di distanza, a mezza duplex o a duplex completa su cavi in fibra ottica a frequenze di 115,2 kbps.

Immuni da EMI, RFI e sovratensioni dei transitori

Un altro vantaggio del sistema a trasmissione in fibra ottica FO 1300 E è la connessione elettrica isolata dei dispositivi. L’interferenza elettromagnetica (EMI) è un altro fenomeno comune in ambienti comuni come impianti industriali, magazzini e piani aziendali. Questo tipo di interferenze può causare il danneggiamento dei dati su seriale o collegamenti Ethernet in rame. I dati trasmessi sul cavo in fibra ottica tuttavia sono del tutto immuni a questo tipo di disturbo, evitando così gli effetti negativi di correnti di equalizzazione della tensione e l’interferenza elettromagnetica sui cavi dei dati. Un media converter da seriale a fibra pertanto consente di creare un’interconnessione tra i dispositivi seriali e la fibra assicurando la trasmissione di dati ottimale, una maggiore disponibilità del sistema e una maggiore flessibilità della struttura della rete per le connessioni punto a punto e per le strutture a stella.

Connessioni in fibra ottica flessibili

L’FO 1300 E funziona a una lunghezza d’onda di 1300 nm, usando un emettitore LED separato e un fotorilevatore sui connettori di tipo SC. È possibile utilizzare qualsiasi dimensione in fibra di vetro singola o multimode.

Considerazioni sulla quantità di corrente

Il calcolo della quantità di corrente è importantissimo nella pianificazione del collegamento della fibra ottica. La quantità di corrente ottica è la quantità di luce necessaria per trasmettere i dati su una distanza tramite una connessione in fibra ottica. La quantità di energia disponibile nella configurazione indica la lunghezza del cavo di fibra ottica tra i media converter seriali nella rete. Le quantità di corrente ottica sono determinanti per aiutare le aziende a evitare la distorsione del segnale. Per sapere come calcolare la quantità di corrente ottica leggere la nostra nota tecnica. La trasmissione e ricezione di dBm sono indicate nelle Specifiche dell'hardware.

Trasmissione di ciascun segnale seriale su più di 10 linee ottiche

Fino a dieci (10) converter da seriale a fibra possono essere raggruppati insieme usando il sistema bus guida DIN TBUS per tensione e dati. In tal modo, il converter seriale funziona come accoppiatore a stella, portando il segnale di input dei dati seriali e distribuendoli a tutte le porte di uscita in fibra ottica.

Funzioni e assistenza di alta qualità

L’FO 1300 E è dotato di funzioni diagnostiche complete che consentono di aumentare la disponibilità del sistema, semplificare l’avviamento e monitorare permanentemente la qualità della trasmissione ottica. In tal modo si avrà una risoluzione dei problemi più efficiente e una manutenzione in loco ridotta. Queste caratteristiche di risparmio di costi e tempo, oltre al supporto tecnico gratuito a livello mondiale, fanno dei converter da seriale a fibra FO 1300 E RS232 una scelta intelligente per i professionisti dell'informatica.

  • Le connessioni possono essere collegati usando un blocco di terminali a vite COMBICON
  • Tensione fornita e segnali di dati instradati tramite connettori a guida DIN
  • Isolamento elettrico di alta qualità tra tutte le interfacce (RS-232, porte in fibra ottica, alimentazione, connettore a guida DIN)
  • Alimentazione ridondante possibile tramite unità di alimentazione del sistema opzionale
  • Approvato per l’utilizzo in zona 2
  • Diagnosi dell’ottica integrata per il monitoraggio continuo dei percorsi della fibra ottica
  • Contatto dell’interruttore galleggiante per la creazione di allarmi portanti in relazione ai percorsi della fibra ottica
  • Direzione del tasso dei dati automatici per tutte le frequenze di dati fino a 115.2 kbps

ROHS Compliant
Din Rail Compliant
Ex Compliant
RS232 Compliant
DNP Compliant

PSI-MOS-RS232/FO 1300 E Technical Specifications

Ambient conditions
Ambient temperature (operation) -20 °C ... 60 °C
Ambient temperature (storage/transport) -40 °C ... 85 °C
Permissible humidity (operation) 30 % ... 95 % (non-condensing)
Altitude 5000 m (For restrictions see manufacturer's declaration)
Degree of protection IP20
Noise immunity EN 61000-6-2:2005
Standards and Regulations
Electromagnetic compatibility Conformance with EMC directive 89/336/EC
Type of test Vibration resistance in acc. with EN 60068-2-6/IEC 60068-2-6
Test result 5g, 10-150 Hz, 2.5 h, in XYZ direction
Type of test Shock in acc. with EN 60068-2-27/IEC 60068-2-27
Test result 15g, 11 ms period, half-sine shock pulse
Shock 15g in all directions in acc. with IEC 60068-2-27
Noise emission EN 55011
Noise immunity EN 61000-6-2:2005
Free from substances that could impair the application of coating according to P-VW 3.10.7 57 65 0 VW-AUDI-Seat central standard
Connection in acc. with standard CUL
Standards/regulations EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
Vibration (operation) In acc. with IEC 60068-2-6: 5g, 150 Hz
Conformance CE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X
UL, USA/Canada 508 listed
508 recognized
Optical interface FO
Number of FO ports 1
Wavelength 1300 nm
Transmission length incl. 3 dB system reserve 27 km (With F-G 50/125 0.7 dB/km at 1300 nm)
22 km (with F-G 62.5/125 0.8 dB/km at 1300 nm)
45 km (With F-E 9/125 0,4 dB/km at 1300 nm)
Transmission medium Multi-mode fiberglass
Single-mode fiberglass
Transmission protocol Transparent to protocol for RS-232 interface
Connection method SC duplex
General
Transmission channels 2 (1/1), RxD, TxD, full duplex
Bit distortion, input ± 35 % (permitted)
Bit distortion, output < 6.25 %
Electrical isolation VCC // V.24 (RS-232)
Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.)
Electromagnetic compatibility Conformance with EMC directive 89/336/EC
Noise emission EN 55011
Net weight 183.78 g
Housing material PA 6.6-FR
Color green
MTBF 549 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day))
113 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day))
Conformance CE-compliant
ATEX II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
UL, USA/Canada 508 listed
508 recognized
Digital outputs
Output name Relay output
Output description Alarm output
Number of outputs 1
Maximum switching voltage 60 V DC
42 V AC
Limiting continuous current 1:00 AM
Power supply
Nominal supply voltage 24 V DC (With UL approval)
Supply voltage range 18 V DC ... 32 V DC
Typical current consumption 100 mA (24 V DC)
Connection method COMBICON plug-in screw terminal block
Serial interface
Interface 1 V.24 (RS-232) interface in acc. with ITU-T V.28, EIA/TIA-232, DIN 66259-1
Connection method D-SUB 9 plug
Transmission medium Copper
Transmission length ≤ 15 m
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 2.5 mm²
Conductor cross section flexible min. 0.2 mm²
Conductor cross section flexible max. 2.5 mm²
Conductor cross section AWG min. 24
Conductor cross section AWG max. 14
Serial transmission speed 115.2 kbps (NRZ)
Dimensions
Width 35 mm
Height 99 mm
Depth 105 mm
PSI-MOS-RS232/FO 1300 E
Environmental Product Compliance
China RoHS Environmentally Friendly Use Period = 50
Reach and RoHS Compliant Reach and RoHS Compliant
Approvals
cUL Listed
cULus Listed
UL Listed
ATEX
EAC
DNV
cUL Recognized
cULus Recognized
UL Recognized
Commercial data
Packing unit 1
Weight per piece 222.7 g
Country of origin Germany
Warranty 1 Year
Classifications
eCl@ss 4.0 27230207
eCl@ss 4.1 27230207
eCl@ss 5.0 27230207
eCl@ss 5.1 27230207
eCl@ss 6.0 27230207
eCl@ss 7.0 27230207
eCl@ss 8.0 19179290
eCl@ss 9.0 19179290
ETIM 2.0 EC001423
ETIM 3.0 EC001423
ETIM 4.0 EC001423
ETIM 5.0 EC000310
ETIM 6.0 EC000310
UNSPSC 6.01 30211506
UNSPSC 7.0901 39121008
UNSPSC 11 39121008
UNSPSC 12.01 39121008
UNSPSC 13.2 43222604
Applicazioni media converter PSI-MOS-RS232/FO 1300 E da seriale a fibra
  • Vicino ad apparecchiature elettriche pesanti
  • In ambienti con interferenza elettrica (EMI) o radio (RFI)
  • In ambienti con sovratensioni dei transitori
  • In impianti industriali, magazzini e piani aziendali
  • Facendo in modo che l’apparecchiatura seriale asincrona possa comunicare a mezza duplex o a duplex completa con frequenze fino a 115.2 kbps, su fibra ottica
Connessioni punto a punto tra i dispositivi seriali sulla fibra
È possibile utilizzare due converter da seriale a fibra PSI-MOS-RS232/FO 1300 E per convertire facilmente un collegamento di dati dal cavo in rame alla fibra ottica.
Punto a punto Diagramma di Rete
Strutture a stella
È possibile collegare i dispositivi RS-232 in una struttura a stella come una rete master/slave. A seconda del numero di linee a stella richieste, vengono collegati più converter da seriale a fibra PSI-MOS-RS232/FO 1300 E collegati a sistemi bus a guida DIN TBUS per tensione e dati. In questo modo si otterranno 10 porte in fibra ottica. Il cablaggio incrociato per i dati RS-232 e per la tensione di alimentazione viene fornito automaticamente tramite il connettore su guida DIN.
Diagramma stelle Network
Diagramma a blocchi
PSI-MOS-RS232/FO 1300 E Diagramma a blocchi
Su
  • Prodotti
  • Applicazioni
  • Su Perle
  • Contattaci
  • Come Acquistare
  • Supporto tecnico
  • Mappa del Sito
  • Note legali
  • Privacy e Cookie

Prodotti di Perle

specialix Chase Research
© 1996 - Perle. Tutti i diritti riservati.
×

Inviaci un'e-mail

Hai domande?

Possiamo fornire ulteriori informazioni sui nostri prodotti oppure prepararti un preventivo


icona di posta elettronicaInvia un'e-mail
contattaci-iconInvia un'e-mail callo-iconaChiamaci