Ricetrasmettitore Ottico SFP

Moduli Ottici Small Form Pluggable

SFP Optical Module

Ricetrasmettitore Ottico SFP

SFP Optical Module
  • Fibra multimodale e monomodale
  • Gigabit Ethernet, Fast Ethernet, Fiber Channel, ATM/SONET, SDH
  • Hot-pluggable con struttura in metallo
  • Installabile in qualsiasi porta compatibile con Cisco o MSA SFF-8472
  • Diagnostica digitale integrata
  • Moduli CWDM disponibili per il supporto delle lunghezze d'onda standard definite da ITU-T G.694.2
  • Temperatura d’esercizio: 0°C a 70°C e -40°C a +85°C
Richiedi preventivo
  • Panoramica
  • SFP-DUPLEX
  • SFP-SIMPLEX ( BiDi )
  • SFP-CWDM
  • 10G SFP+ & XFP

I ricetrasmettitori ottici SFP di Perle sono connettori media hot-swappable e compatti che forniscono una connettività istantanea su fibra alla tua apparecchiatura in rete. Si tratta di un modo efficiente dal punto di vista dei costi per collegare un dispositivo a rete singola a un'ampia serie di distanze e tipi di cavi in fibra.

Grazie all'eliminazione della necessità di mantenere unità o dispositivi di riserva dei vari tipi di fibra per le riparazioni o gli aggiornamenti della rete, i ricetrasmettitori ottici a innesto di piccolo formato riducono gli inventari delle apparecchiature di rete. Gli SFP offrono in un unico prodotto la flessibilità di espandere la velocità (Fast Ethernet e 1, 10 o 40 Gigabit), e/o la distanza (da 220 m a 80 km).

Anche gli aggiornamenti di rete diventano più semplici dal momento che gli SFP sono connettori in fibra intercambiabili che possono adattarsi a qualsiasi rete esistente. Ad esempio, con la sola sostituzione del ricetrasmettitore ottico a innesto, un Media Converter utilizzato in origine su una rete multimodo può essere riconfigurato per lavorare su una rete CWDM.

I ricetrasmettitori ottici SFP di Perle possono venire utilizzati in maniera intercambiabile su un'ampia serie di prodotti SFP compatibili con Cisco o MSA. Questi possono venire mescolati in combinazioni di 1000BASE-SX, 1000BASE-LX/LH, 1000BASE-EX, 1000BASE-ZX o 1000BASE-BX10-D/U porta per porta.

I ricetrasmettitori ottici SFP di Perle sono progettati per venire utilizzati in associazione a Media Converter SFP di Perle, Switch Ethernet industriali, Console Server IOLAN SCG e a componenti di terze parti che supportano i ricetrasmettitori SFP. Seleziona la relativa scheda di per visualizzare i modelli Duplex, Simplex (BiDi), CWDM o 10G SFP+ e XFP.

Caratteristiche del ricetrasmettitore SFP di Perle

Ampia gamma di applicazioni in fibra Con questi moduli è possibile utilizzare protocolli di rete popolari come Ethernet, Fibre Channel, ATM/SONET OC-X e SDH STM-X
Compatibile con IOS di Cisco Tutti gli SFP di Perle possono essere installati in tutti i router e gli switch basati su SFP di Cisco e sono completamente compatibili con il software IOS di Cisco.
Compatibile con MSA SFF-8472 Tutti gli SFP sono completamente compatibili con il Multi Sourcing Agreement (MSA).
Informazioni diagnostiche digitali migliorate (DOM o DMI) Fornisce informazioni diagnostiche digitali leggibili per apparecchiature gestite allo scopo di assistere gli amministratori di rete nella manutenzione e nella gestione della rete
Modelli per temperature industriali Sono disponibili modelli con struttura per temperature industriali (da -40°C a 85°C) pensati per ambienti dalle temperature estreme
Modelli CWDM I ricetrasmettitori ottici a innesto CWDM aumentano la capacità della rete trasmettendo canali di dati multipli su lunghezze d'onda ottiche distinte (da 1.470 nm a 1.610 nm) tramite la stessa coppia di fibra. Queste lunghezze d'onda sono compatibili con lo standard CWDM ITU G.694.
Sicurezza EN 60950-1:2006+A11+A1+A12+A2
Emissioni CISPR 32:2015 + COR1:2016 (Class B) / EN55032:2015+AC:2016 (Class B)
EN55011 (CISPR11)
EMC e Immunità CISPR 24:2010/EN 55024:2010
Sicurezza laser I ricetrasmettitori ottici su fibra in questo dispositivo adempiono i requisiti di sicurezza laser di Classe 1 per gli standard IEC-60825 FDA/CDRH e sono conformi a 21CFR1040.10 e 21CFR1040.11.
EN 60825-1:2014
EN 60825-2:2004+A1+A2
Ambientale Conforme a Reach, RoHS e RAEE
Altro ECCN: EAR99
Numero HTSUS: 8517.62.0020
Garanzia di due anni con restituzione in fabbrica
EU Declaration of Conformity

Select a High Speed Model below to obtain a Part Number -----OR----- Click Here to view Fast Ethernet, SONET OC-3, G.957, SDH STM-1 Models

SFP Model
Connector
Speed
Type
DOM
/ DMI
Temp
Transmit
Receive
Power
Budget
(dB)
Wave-
length
(nm)
Fiber
Type
Core
Size
(um)
Modal
Band-
width
(MHz Km)
Operating
Distance
(dBm)
(dBm)
Min
Max
Min
Max
PSFP-1000-M2LC05 Dual LC 1.25 Gbps 1000Base-SX
Fibre Channel
FICON

(Alternate to Cisco:
GLC-SX-MM)

No 0 to 70C
(32F to 158F )
-9.5 -4.0 -17.0 -3.0 7.5 850 MMF 62.5 160 220 m
(722 ft)
62.5 200 275 m
(902 ft)
50 400 500 m
(1,640 ft)
50 500 550 m
(1,804 ft)
50 2000 1000 m
(3281 ft)
PSFP-1000D-M2LC05 Dual LC 1.25 Gbps 1000Base-SX
Fibre Channel
FICON

(Alternate to Cisco:
SFP-GE-S)

Yes 0 to 70C
(32F to 158F )
-9.5 -4.0 -17.0 -3.0 7.5 850 MMF 62.5 160 220 m
(722 ft)
62.5 200 275 m
(902 ft)
50 400 500 m
(1,640 ft)
50 500 550 m
(1,804 ft)
50 2000 1000 m
(3281 ft)
PSFP-1000D-M2LC05-XT Dual LC 1.25 Gbps 1000Base-SX
Fibre Channel
FICON

(Alternate to Cisco:
SFP-GE-S)

Yes -40 to 85C
(-40F to 185F)
-9.5 -3.0 -18.0 -3.0 8.5 850 MMF 62.5 160 220 m
(722 ft)
62.5 200 275 m
(902 ft)
50 400 500 m
(1,640 ft)
50 500 550 m
(1,804 ft)
50 2000 1000 m
(3281 ft)
PSFP-1000D-M2LC2 Dual LC 1.25 Gbps 1000Base-LX
Fibre Channel
FICON
Yes 0 to 70C
(32F to 158F )
-9.0 -1.0 -19.0 -1.0 10.0 1310 MMF 62.5 160 2 km
(1.2 mi)
50 500 1000 m
(3281 ft)
PSFP-1000D-M2LC2-XT Dual LC 1.25 Gbps 1000Base-LX
Fibre Channel
FICON
Yes -40 to 85C
(-40F to 185F)
-9.0 -1.0 -19.0 -1.0 10.0 1310 MMF 62.5 160 2 km
(1.2 mi)
50 500 1000 m
(3281 ft)
PSFP-2GD-M2LC03 Dual LC up to 2.67 Gbps 1000Base-SX
Fibre Channel
FC-2
FICON
GR253
SONET OC-48
G.957
SDH STM-16
Yes 0 to 70C
(32F to 158F )
-10 -3 -18 -3 8 850 MMF 50 500 300 m
(984 ft)
PSFP-4GD-M2LC05 Dual LC Multi-Rate -
1.063 Gbps
2.125 Gbps
4.25 Gbps
1000Base-SX
Fibre Channel
FC-1,2,4
FICON
Yes 0 to 70C
(32F to 158F )
-9 -2.5 -15 0 6 850 MMF 62.5 200 300 m
(984 ft)
50 500 500 m
(1640 ft)
PSFP-1000-S2LC10 Dual LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-LX / LH
Fibre Channel
FC-1
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
GLC-LH-SM)

No 0 to 70C
(32F to 158F )
-9.5 -3.0 -21.0 -3.0 11.5 1310 MMF *** 62.5 500 550 m
(1,804 ft)
50 400 550 m
(1,804 ft)
50 400 550 m
(1,804 ft)
SMF ** -
10 km
(6.2 mi)
PSFP-1000D-S2LC10 Dual LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-LX / LH
Fibre Channel
FC-1
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
SFP-GE-L)

Yes 0 to 70C
(32F to 158F )
-9.0 -3.0 -23.0 -3.0 14.0 1310 MMF *** 62.5 500 550 m
(1,804 ft)
50 400 550 m
(1,804 ft)
50 400 550 m
(1,804 ft)
SMF ** -
10 km
(6.2 mi)
PSFP-1000D-S2LC10-XT Dual LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-LX / LH
Fibre Channel
FC-1
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
SFP-GE-L)

Yes -40 to 85C
(-40F to 185F)
-9.0 -3.0 -23.0 -3.0 14.0 1310 MMF *** 62.5 500 550 m
(1,804 ft)
50 400 550 m
(1,804 ft)
50 400 550 m
(1,804 ft)
SMF ** - 10 km
(6.2 mi)
PSFP-4GD-S2LC10 Dual LC Multi-Rate -
1.063 Gbps
2.125 Gbps
4.25 Gbps
1000Base-LX / LH
Fibre Channel
FC-1,2,4
FICON
Yes 0 to 70C
(32F to 158F )
-8.0 0.0 -18.0 -3.0 10.0 1310 SMF ** - 10,000 m
(32,821 ft)
PSFP-1000D-S2LC20 Dual LC 1.25 Gbps 1000Base-EX
Fibre Channel
FICON

(Alternate to Cisco:
SFP-GE-L-20)

Yes 0 to 70C
(32F to 158F )
-9.0 -3.0 -23.0 -3.0 14.0 1310 SMF ** - 20 km
(12.4 mi)
PSFP-1000D-S2LC20-XT Dual LC 1.25 Gbps 1000Base-EX
Fibre Channel
FICON

(Alternate to Cisco:
SFP-GE-L-RGD-20)

Yes -40 to 85C
(-40F to 185F)
-9.0 -3.0 -23.0 -3.0 14.0 1310 SMF ** - 20 km
(12.4 mi)
PSFP-2GD-S2LC20 Dual LC up to 2.67 Gbps 1000Base-LX / LH
Fibre Channel
FC-2
FICON
GR253
SONET OC-48
G.957
SDH STM-16
Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -18.0 -3.0 13.0 1310 SMF ** - 20,000 m
(65,617 ft)
PSFP-1000D-S2LC40 Dual LC 1.25 Gbps 1000Base-EX
Fibre Channel
FICON

(Alternate to Cisco:
SFP-GE-L-40)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -23.0 -3.0 18.0 1310 SMF ** - 40 km
(25 mi)
PSFP-1000D-S2LC40-XT Dual LC 1.25 Gbps 1000Base-EX
Fibre Channel
FICON

(Alternate to Cisco:
SFP-GE-L-RGD-40)

Yes -40 to 85C
(-40F to 185F)
-5.0 0.0 -23.0 -3.0 18.0 1310 SMF ** - 40 km
(25 mi)
PSFP-1000D-S2LC80 Dual LC 1.25 Gbps 1000Base-ZX
Fibre Channel
FICON

(Alternate to Cisco:
SFP-GE-Z)

Yes 0 to 70C
(32F to 158F )
0.0 5.0 -23.0 -3.0 23.0 1550 SMF ** - 80 km
(50 mi)
PSFP-1000D-S2LC80-XT Dual LC 1.25 Gbps 1000Base-ZX
Fibre Channel
FICON

(Alternate to Cisco:
SFP-GE-Z-RGD)

Yes -40 to 85C
(-40F to 185F)
0.0 5.0 -23.0 -3.0 23.0 1550 SMF ** - 80 km
(50 mi)

Protocols: Fast Ethernet, SONET OC-3, G.957, SDH STM-1

PSFP-100-M2LC2 Dual LC Up to 155 Mbps 100Base-FX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100FX)

No 0 to 70C
(32F to 158F )
-19.0 -14.0 -32.0 -3.0 13.0 1310 MMF 50.0 500 5km *
(3.1 mi)
62.5 2km
(1.2 mi)
PSFP-100D-M2LC2-XT Dual LC Up to 155 Mbps 100Base-FX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100FX-RGD)

Yes -40 to 85C
(-40F to 185F)
-20.0 -14.0 -31.0 -3.0 11.0 1310 MMF 50.0 500 5km *
(3.1 mi)
62.5 2km
(1.2 mi)
PSFP-100D-M2LC05 Dual LC Up to 155 Mbps 100Base-SX
SONET OC-3
SDH STM-1
Yes 0 to 70C
(32F to 158F )
-8.0 -3.0 -19.0 -3.0 11.0 850 MMF 50.0 500 550 m
(1804 ft)
62.5 200 300 m
(990 ft)
PSFP-100D-S2LC10 Dual LC up to 155 Mbps 100Base-LX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100LX)

Yes 0 to 70C
(32F to 158F )
-14.0 -8.0 -32.0 -3.0 18.0 1310 SMF ** - 10km
(6.2 mi)
PSFP-100D-S2LC10-XT Dual LC up to 155 Mbps 100Base-LX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100LX-RGD)

Yes -40 to 85C
(-40F to 185F)
-14.0 -8.0 -32.0 -3.0 18.0 1310 SMF ** - 10km
(6.2 mi)
PSFP-100D-S2LC40 Dual LC up to 155 Mbps 100Base-EX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100EX)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -34.0 -3.0 29.0 1310 SMF ** - 40km
(25 mi)
PSFP-100D-S2LC80 Dual LC up to 155 Mbps 100Base-ZX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100ZX)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -34.0 -3.0 29.0 1550 SMF ** - 80km
(50 mi)

* 1db/km multimode 50/125 micron fiber cable

** ITU-T G.652 SMF as specified by the IEEE 802.3z standard.

*** A mode-conditioning adapter as specified by the IEEE standard, is required regardless of the span length. Note how the mode conditioning adapter for 62.5-um fibers has a different specification from the mode-conditioning adapter for 50-um fibers.

Select a High Speed Model below to obtain a Part Number -----OR----- Click Here to view Fast Ethernet, SONET OC-3, G.957, SDH STM-1 Models

Single Fiber Models Recommended use in pairs

SFP Model
Connector
Speed
Type
DOM
/ DMI
Case Temp
Transmit
Receive
Power
Budget
(dB)
Wave-
length
(nm)
Fiber
Type
Core
Size
(um)
Operating
Distance
(dBm)
(dBm)
Min
Max
Min
Max
PSFP-1000D-M1LC2D Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX10-U
Fibre Channel
FICON
SONET OC-24-LR-1
Yes 0 to 70C
(32F to 158F )
-10 -4.0 -22.0 -3.0 12.0 1550 / 1310 MMF ** 2 km
(1.24 mi)
PSFP-1000D-M1LC2U Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX10-U
Fibre Channel
FICON
SONET OC-24-LR-1
Yes 0 to 70C
(32F to 158F )
-10 -4.0 -22.0 -3.0 12.0 1310 / 1550 MMF ** 2 km
(1.24 mi)
PSFP-1000-S1LC10U Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX10-U
Fibre Channel
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
GLC-BX-U)

No 0 to 70C
(32F to 158F )
-9.0 -3.0 -20.0 -3.0 11.0 1310 / 1490 SMF ** 10 km
(6.2 mi)
PSFP-1000-S1LC10D Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX10-D
Fibre Channel
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
GLC-BX-D)

No 0 to 70C
(32F to 158F )
-9.0 -3.0 -20.0 -3.0 11.0 1490 / 1310 SMF ** 10 km
(6.2 mi)
PSFP-1000D-1LC10U-XT Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX10-U
Fibre Channel
FICON
SONET OC-24-LR-1
Yes -40 to 85C
(-40F to 185F )
-9.0 0.0 -23.0 -3.0 14.0 1310 / 1490 SMF ** 10 km
(6.2 mi)
PSFP-1000D-1LC10D-XT Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX10-D
Fibre Channel
FICON
SONET OC-24-LR-1
Yes -40 to 85C
(-40F to 185F )
-9.0 0.0 -23.0 -3.0 14.0 1490 / 1310 SMF ** 10 km
(6.2 mi)
PSFP-1000D-S1LC40U Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX
Fibre Channel
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
GLC-BX-U-40)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -23.0 -3.0 18.0 1310 / 1490 SMF ** 40 km
(25 mi)
PSFP-1000D-S1LC40D Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX
Fibre Channel
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
GLC-BX-D-40)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -23.0 -3.0 18.0 1490 / 1310 SMF ** 40 km
(25 mi)
PSFP-1000D-S1LC60U Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX
Fibre Channel
FICON
SONET OC-24-LR-1
GLC-BX-U-60
Yes 0 to 70C
(32F to 158F )
-1.0 4.0 -26.0 -3.0 25.0 1490 / 1550 SMF ** 60 km
(37 mi)
PSFP-1000D-S1LC60D Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX
Fibre Channel
FICON
SONET OC-24-LR-1
GLC-BX-D-60
Yes 0 to 70C
(32F to 158F )
-1.0 4.0 -26.0 -3.0 25.0 1550 / 1490 SMF ** 60 km
(37 mi)
PSFP-1000D-S1LC80U Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX
Fibre Channel
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
GLC-BX-U-80)

Yes 0 to 70C
(32F to 158F )
-1.0 4.0 -26.0 -3.0 25.0 1490 / 1550 SMF ** 80 km
(50 mi)
PSFP-1000D-S1LC80D Single LC Dual Rate -
1.25 Gbps,
1.063 Gbps
1000Base-BX
Fibre Channel
FICON
SONET OC-24-LR-1

(Alternate to Cisco:
GLC-BX-D-80)

Yes 0 to 70C
(32F to 158F )
-1.0 4.0 -26.0 -3.0 25.0 1550 / 1490 SMF ** 80 km
(50 mi)

Protocols: Fast Ethernet, SONET OC-3, SDH STM-1

PSFP-100D-S1LC10U Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-U)

Yes 0 to 70C
(32F to 158F )
-14.0 -8.0 -32.0 -3.0 18.0 1310 / 1550 SMF ** 10 km
(6.2 mi)
PSFP-100D-S1LC10U-XT Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-U-RGD)

Yes -40 to 85C
(-40F to 185F )
-14.0 -8.0 -32.0 -3.0 18.0 1310 / 1550 SMF ** 10 km
(6.2 mi)
PSFP-100D-S1LC10D Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-D)

Yes 0 to 70C
(32F to 158F )
-14.0 -8.0 -32.0 -3.0 18.0 1550 / 1310 SMF ** 10 km
(6.2 mi)
PSFP-100D-S1LC10D-XT Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-D-RGD)

Yes -40 to 85C
(-40F to 185F )
-14.0 -8.0 -32.0 -3.0 18.0 1550 / 1310 SMF ** 10 km
(6.2 mi)
PSFP-100D-S1LC20U Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-U)

Yes 0 to 70C
(32F to 158F )
-14.0 -8.0 -32.0 -3.0 18.0 1310 / 1550 SMF ** 20 km
(12.4 mi)
PSFP-100D-S1LC20D Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-D)

Yes 0 to 70C
(32F to 158F )
-14.0 -8.0 -32.0 -3.0 18.0 1550 / 1310 SMF ** 20 km
(12.4 mi)
PSFP-100D-S1LC40U Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-U)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -32.0 -3.0 27.0 1310 / 1550 SMF ** 40 km
(25 mi)
PSFP-100D-S1LC40D Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-D)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -32.0 -3.0 27.0 1550 / 1310 SMF ** 40 km
(25 mi)
PSFP-100D-S1LC80U Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-U)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -32.0 -3.0 27.0 1490 / 1550 SMF ** 80 km
(50 mi)
PSFP-100D-S1LC80D Single LC Up to 155 Mbps 100Base-BX
SONET OC-3
SDH STM-1

(Alternate to Cisco:
GLC-FE-100BX-D)

Yes 0 to 70C
(32F to 158F )
-5.0 0.0 -32.0 -3.0 27.0 1550 / 1490 SMF ** 80 km
(50 mi)

**ITU-T G.652 SMF as specified by the IEEE 802.3z standard.

Single Mode / Single Fiber

Connect copper ports over a single fiber strand ( also referred to as “Bi-Directional” BiDi )
When Single Strand fiber is used, a pair of Single Fiber Media Converters is needed for the copper to fiber conversion. Perle Single Fiber Media Converters are also referred to as “Up/Down” models. For example the PSFP-1000-S1LC10U (“Up”) and PSFP-1000-S1LC10D (“Down”), shown below, must be used in pairs. An “Up” must be matched with a “Down” peer to deal with transmit and receive frequencies separately.

Single Mode Fiber Diagram PSFP-1000-S1LC10UPSFP-1000-S1LC10D

The majority of installations for single mode fiber media converters are of the “dual connector” or “dual fiber” type where one fiber connection is used for transmit, the other for receive. These are physically “crossed” to match up the Transmit/Receive links.

However, to reduce costs, or where there are limits on available fiber, WDM technology may be utilized. WDM uses separate transmit and receive frequencies to communicate on a single fiber strand. WDM technology relies on the fact that optical fibers can carry many wavelengths of light simultaneously without interaction between each wavelength. Thus, a single fiber can carry many separate wavelength signals or channels simultaneously.

So remember, if Single Strand fiber is used, you will need an “Up” Media Converter on one side and a “Down” Media Converter on the other for copper to fiber conversion.

Perle offers a wide variety of Single Fiber (“Up/Down”) Media Converters to connect 10BaseT, Fast Ethernet and Gigabit to single fiber. Whether you need Managed or Unmanaged, Standalone or Modular Chassis Based, 20km or 120km, Perle has the right model to meet your fiber conversion requirement.

Select a Model to obtain a Part Number

CWDM ( coarse wavelength division multiplexing ) Models

SFP Model
Connector
Speed
Type
DOM
/ DMI
Case Temp
Transmit
Receive
Power
Budget
(dB)
Wave-
length
(nm)
Fiber
Type
Core
Size
(um)
Operating
Distance
(dBm)
(dBm)
Min
Max
Min
Max
PSFP-CWDM-SFP-1470 Dual LC up to 2.67 Gbps 1000Base-CWDM
Fibre Channel
Yes 0 to 70C
(32F to 158F )
0.0 5.0 -28.0 -9.0 28.0 1470 SMF ** 80 km
(50 mi)
PSFP-CWDM-SFP-1490 Dual LC up to 2.67 Gbps 1000Base-CWDM
Fibre Channel
Yes 0 to 70C
(32F to 158F )
0.0 5.0 -28.0 -9.0 28.0 1490 SMF ** 80 km
(50 mi)
PSFP-CWDM-SFP-1510 Dual LC up to 2.67 Gbps 1000Base-CWDM
Fibre Channel
Yes 0 to 70C
(32F to 158F )
0.0 5.0 -28.0 -9.0 28.0 1510 SMF ** 80 km
(50 mi)
PSFP-CWDM-SFP-1530 Dual LC up to 2.67 Gbps 1000Base-CWDM
Fibre Channel
Yes 0 to 70C
(32F to 158F )
0.0 5.0 -28.0 -9.0 28.0 1530 SMF ** 80 km
(50 mi)
PSFP-CWDM-SFP-1550 Dual LC up to 2.67 Gbps 1000Base-CWDM
Fibre Channel
Yes 0 to 70C
(32F to 158F )
0.0 5.0 -28.0 -9.0 28.0 1550 SMF ** 80 km
(50 mi)
PSFP-CWDM-SFP-1570 Dual LC up to 2.67 Gbps 1000Base-CWDM
Fibre Channel
Yes 0 to 70C
(32F to 158F )
0.0 5.0 -28.0 -9.0 28.0 1570 SMF ** 80 km
(50 mi)
PSFP-CWDM-SFP-1590 Dual LC up to 2.67 Gbps 1000Base-CWDM
Fibre Channel
Yes 0 to 70C
(32F to 158F )
0.0 5.0 -28.0 -9.0 28.0 1590 SMF ** 80 km
(50 mi)
PSFP-CWDM-SFP-1610 Dual LC up to 2.67 Gbps 1000Base-CWDM
Fibre Channel
Yes 0 to 70C
(32F to 158F )
0.0 5.0 -28.0 -9.0 28.0 1610 SMF ** 80 km
(50 mi)

**ITU-T G.652 SMF as specified by the IEEE 802.3z standard.

Su
  • Prodotti
  • Applicazioni
  • Su Perle
  • Contattaci
  • Come Acquistare
  • Supporto tecnico
  • Mappa del Sito
  • Note legali
  • Privacy e Cookie

Prodotti di Perle

specialix Chase Research
© 1996 - Perle. Tutti i diritti riservati.
×

Inviaci un'e-mail

Hai domande?

Possiamo fornire ulteriori informazioni sui nostri prodotti oppure prepararti un preventivo


icona di posta elettronicaInvia un'e-mail
contattaci-iconInvia un'e-mail callo-iconaChiamaci