Estensore Rame 10/100/1000 per Temperature Industriali

Estensori Ethernet 10/100/1000 per Temperature Industriali

Estensori Ethernet 10/100/1000 per Temperature Industriali

Estensori Ethernet 10/100/1000 per Temperature Industriali
Richiedi preventivo
  • Ampliate la comunicazione 10/100/1000Base-T Ethernet fino a 3 chilometri su doppino telefonico 24 a 2 cavi
  • Design robusto per resistere alle temperature da -40°C a +75°C tipiche degli ambienti industriali
  • Alta velocità: velocità di linea aggregata fino a 200+ mbps
  • Funzionamento trasparente per tutti i protocolli Ethernet inclusi i pacchetti 802.1Q VLAN e gli schemi di compressione video IP
  • Una o quattro porte 10/100/1000 Ethernet
  • Funzionalità avanzate: Link Pass-Through*, Interlink Fault Feedback*, Plug and Play, Auto-MDIX e Loopback
  • Panoramica
  • Specifiche di prodotto
  • Diagrammi
  • Documentazione
  • Come Acquistare

Se volete ampliare i servizi Ethernet e andare oltre il limite generale dei 100 metri dello standard IEEE 802.3 in temperature industriali e se un nuovo cablaggio in fibra è troppo costoso, gli Estensori Ethernet sono la soluzione perfetta. Gli Estensori Ethernet Perle estendono in modo trasparente fino a quattro collegamenti 10/100/1000 Ethernet su cavi di rame. Utilizzate un doppino telefonico (CAT5/6/7), un cavo coassiale o un cablaggio di rame esistente già in uso nei circuiti di allarme, in circuiti E1/T1, RS-232, RS-422, RS-485 e applicazioni CCTV e CATV.

Le apparecchiature utilizzate per la gestione del traffico, i tubi di petrolio e gas, il monitoraggio delle condizioni atmosferiche e le applicazioni industriali e all'aperto devono funzionare a temperature che non possono essere supportate da un Estensore Ethernet commerciale. Grazie alla capacità di funzionare a temperature da -40°C a +75°C e a una solida struttura in acciaio, questi semplici ed efficaci Estensori Ethernet in rame da punto a punto sono ideali per ampliare la distanza tra due dispositivi Ethernet industriali impiegati in ambienti gravosi e a temperature estreme, come videocamere di sicurezza, punti di accesso wireless, allarmi, dispositivi di controllo del traffico, sensori e dispositivi di monitoraggio.

Le funzioni avanzate di Perle, come Link Pass-Through*, Interlink Fault Feedback* e Loopback, consentono agli amministratori di rete di avere tutto sotto controllo per risolvere i problemi in modo più efficiente e con meno attività di manutenzione sul campo. Queste funzionalità permettono di risparmiare tempo e denaro e sono affiancate da una garanzia a vita e da assistenza tecnica mondiale gratuita. Per questo gli Estensori Ethernet Perle sono la scelta ideale per i professionisti IT. Gli Estensori Ethernet eX-S1110 sono anche disponibili con l'assistenza per intervalli di temperature commerciali, reti gestite con sicurezza AAA e applicazioni ad alta densità.

Caratteristiche degli Estensori Gigabit Ethernet eX-S1110-XT

Ethernet oltre il doppino telefonico Ampliate un collegamento Ethernet oltre il cablaggio di categoria 5e, 6 e 7 fino a 3 chilometri
Ethernet anche su cavo coassiale Il collegamento Ethernet è adesso possibile su cavo coassiale da 75 ohm
Prestazioni ad alta velocità Utilizzano la tecnologia VDSL2 di seconda generazione (ITU-T Recommendation G.993.). Durante l'uso con "Profile 30a", gli Estensori Ethernet Perle possono fornire una capacità di velocità di linea aggregata superiore a 200 mbps.

La distanza e le prestazioni effettive variano in base al tipo, alle dimensioni e alle condizioni del cavo utilizzato.
Funzionamento Plug and Play Gli Estensori Ethernet Perle configurano automaticamente il collegamento interlink VDSL. L'associazione tra pari CO/CPE viene determinata automaticamente dall'Estensore Ethernet, senza necessità di impostare l'accoppiamento VDSL CO/CPE.

Dopo aver stabilito il collegamento, entrambe le estremità regolano automaticamente i parametri VDSL necessari per ottimizzare il livello di larghezza di banda possibile sul collegamento in rame.
Link Pass-Through* Con Link Pass-Through lo stato del collegamento 10/100/1000Base-T Ethernet "passa attraverso" il collegamento VDSL al collegamento 10/100/1000Base-T Ethernet sul dispositivo peer remoto. Un interruttore gestito sul dispositivo remoto può quindi riferire lo stato (collegamento attivo o inattivo) al sistema di gestione della rete per rilevare e risolvere tempestivamente eventuali errori.

Gli Estensori Ethernet della concorrenza privi di questa funzionalità non sono in grado di rilevare o segnalare condizioni di errore.
Interlink Fault Feedback* Simile alla funzione Link Pass-Through, una perdita del collegamento VDSL termina le porte 10/100/1000 Ethernet su ciascuna estremità fino al ripristino del collegamento stesso.
Auto-Negotiation Il Convertitore di Media supporta la funzione Auto-Negotiation sull'interfaccia 10/100/1000Base-T.
Auto-MDIX La funzione Auto-MDIX (Automatic Medium-Dependent Interface crossover) rileva il segnale sull'interfaccia RJ45 10/100/1000 Ethernet e determina il tipo di cavo collegato (straight-through o crossover) adottando automaticamente un collegamento compatibile.
Velocità fissa e duplex Alcuni dispositivi Ethernet richiedono una velocità fissa e duplex per poter eseguire l'autonegoziazione. Disabilitando l'autonegoziazione sull'Estensore Ethernet, è possibile configurare una velocità fissa di 10, 100 o 1000 mbps oltre che full-duplex o half-duplex tramite interruttori DIP.
VLAN Transparent ai pacchetti VLAN (802.1Q) tagged.
Protocolli Transparent a compressione video IP Pienamente transparent a schemi di compressione video IP quali MPEG-4, H.264 ed MJPEG.
Fascetta pressacavi Tutti i modelli sono provvisti di una fascetta pressacavi che garantisce una connessione sicura al Estensore Ethernet. Ideale per ambienti soggetti a vibrazioni.
Loopback Se la funzione è abilitata, viene eseguito un loopback sull'interlink VDSL in rame.

* Disponibile sui modelli con 1 porta.

Ethernet eX-1S1110-XT eX-4S1110-XT
Port 1 port RJ45 – 10/100/1000Base-T - Shielded 4 port RJ45 – 10/100/1000 Base-T - Shielded
Auto-MDIX Auto-MDIX enables proper operation with either straight-through or crossover cabling
Distance Distance up to 100 meters (328 feet) as per IEEE 802.3
Maximum Frame Size 1522 bytes
VDSL – Interlink
RJ45, BNC, Terminal Block

Ethernet Extenders must be connected in pairs using unconditioned wire. Circuits that run through signal equalization equipment are not permitted.

TIP and RING are polarity insensitive. Surge suppression of 400 volts between TIP and RING. Choice of RJ45, BNC or terminal block models for VDSL link connector:

  • RJ45 – RING pin 4, TIP pin 5 (TIA 568 A/B)
  • BNC – Coaxial 50 and 75 ohm cable with BNC connector
  • Terminal Block – 2 position screw connectors for use with twisted pair telephone, alarm or serial cabling between 19 (0.9 mm) and 26 AWG (0.44 mm).
VDSL2 Line Rate/Reach Actual distance and rates experienced will depend on condition and gauge of wire used. This Rate/Reach table applies to 24 AWG (0.5 MM) twisted pair wiring on RJ45 (RJ) and terminal block (TB) models.

High Speed Asymmetric
Reach (Distance) VDSL Rate (Mbps)
feet meters Downstream Upstream
500 152 101 92
1000 305 101 63
1500 457 90 38
2000 610 62 24
2500 762 55 10
3000 914 42 5
3500 1000 35 3
High Speed Symmetric
Reach (Distance) VDSL Rate (Mbps)
feet meters Downstream Upstream
500 152 101 101
1000 305 85 101
1500 457 62 47
2000 610 60 29
2500 762 44 14
3000 914 30 7
3500 1000 29 4
Long Reach Symmetric
Reach (Distance) VDSL Rate (Mbps)
feet meters Downstream Upstream
500 152 53 44
1000 305 53 43
2500 762 39 18
4000 1219 25 4
5500 1676 17 1.9
7000 2134 8 2.3
7500 2286 7 2.2
8000 2438 5 2.2
Long Reach Asymmetric
Reach (Distance) VDSL Rate (Mbps)
feet meters Downstream Upstream
500 152 78 16
1000 305 78 16
2500 762 55 10
4000 1219 31 0.8
5500 1676 20 0.6
7000 2134 11 0.6
7500 2286 10 0.6
8000 2438 8 0.6
Power eX-1S1110-XT eX-4S1110-XT
Input Supply Voltage 9 - 30 vDC, unregulated (12 vDC Nominal)
Current 350 mA 500 mA
Power Consumption (watts) 4.2 6.0
Power Connectors 5.5mm x 9.5mm x 2.1mm barrel socket and 2 pin terminal Block
power connector

eX-1S1110-XT Power connection

connector plug
power connector

eX-4S1110-XT Power connection

connector plug
Power Adapter
Universal AC/DC adapter Optional Industrial Temperature 100-240v AC, regulated 12V DC adapter
Indicators
Power / TST This green LED is turned on when power is applied to the Ethernet Extender. Otherwise it is off. The LED will blink when in Loopback test mode.
CO - Local Ethernet Extender is operating in CO VDSL mode
CPE - remote Ethernet Extender is operating in CPE VDSL mode
ILNK Indicates Link Status and activity on the Interlink (VDSL) port
ETH Indicates link status and activity on Ethernet port(s).
Switches eX-1S1110-XT eX-4S1110-XT
Access All switch settings are accessible through a side opening in the chassis
Ex dipswitch

Dip Switches

Ex dipswitch
Rate/Reach Two switches enable the user to select the right balance between speed and distance for their environment.
Signal to Noise Ratio Selectable Signal to Noise Ratio (SNR) of 6dB or 9dB. The higher SNR number provides better impulse noise protection but lowers performance.
Auto-Negotiation (802.3u) Enabled (Default) - The Ethernet Extender uses 802.3u Auto-negotiation on the 10/100/1000Base-T interface. It is set to advertise full duplex.

Disabled - The Ethernet Extender sets the port according to the position of the speed and duplex switches.

Link Mode Standard (Default) – The 10/100/1000Base-T link remains active independent of the state of the Ethernet link on its remote peer.

Link Pass-Through- the state of the 10/100/1000Base-T Ethernet connection is “passed through” or propagated across the VDSL link to the 10/100/1000Base-T Ethernet link on its remote Ethernet Extender peer. This enables a managed switch to report the state of the remote device to its network management system.

N/A
Interlink Fault Feedback Enabled - A loss of VDSL link will drop the 10/100/1000 Ethernet port on each end until the link recovers

Disabled (Default) – The state of the VDSL link is not propagated to the 10/100/1000Base-T port

N/A
Loopback Enabled - The VDSL interlink will perform a loopback function, retransmitting all received Ethernet frames back to its peer.

Disabled (Default - Up)

Set Ethernet Speed
(Port 1)
When Auto-Negotiation switch is disabled, fixed speed can be set at 1000 (Default) or 100 or 10
Set Ethernet Duplex
(Port 1)
When Auto-Negotiation switch is disabled, Duplex can be set at Full (Default) or Half
Environmental Specifications eX-1S1110-XT eX-4S1110-XT
Operating Temperature -40°C to 75°C (-40°F to 167°F)
Storage Temperature minimum range of -40°C to 85°C (-40°F to 185°F)
Operating Humidity 5% to 90% non-condensing
Storage Humidity 5% to 95% non-condensing
Operating Altitude Up to 3,048 meters (10,000 feet)
Heat Output (BTU/HR) 14.3 20.5
MTBF (Hours)* 466,861 365,077
Mounting
Din Rail Kit Optional
Rack Mount Kit Optional
Product Weight and Dimensions
Weight 0.33 kg, 0.73 lbs 0.47 kg, 1.04 lbs
Dimensions 120 x 80 x 35 mm, 4.7 x 3.1 x 1.4 inches 130 x 115 x 35 mm, 5.1 x 4.5 x 1.4 inches
Packaging
Shipping Weight 0.46 kg, 1.01 lbs 0.65 kg, 1.43 lbs
Shipping Dimensions 170 x 260 x 70 mm, 6.7 x 10.2 x 2.8 inches
Regulatory Approvals
Emissions FCC Part 15 Class A, EN55022 Class A
CISPR 32:2015/EN 55032:2015 (Class A)
EN61000-3-2
Immunity CISPR 24:2010/EN 55024:2010
Electrical Safety UL/EN/IEC 62368-1
CAN/CSA C22.2 No. 62368-1
UL 60950-1
IEC 60950-1(ed 2); am1, am2
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013
CE
Environmental Reach, RoHS and WEEE Compliant
Other ECCN: 5A991
HTSUS Number: 8517.62.0020
Perle Lifetime warranty

*Calculation model based on MIL-HDBK-217-FN2 @ 30 °C

Ampliate la comunicazione 10/100/1000 Ethernet su doppino telefonico o cavo coassiale in aree soggette a temperature estreme

Create collegamenti Ethernet che superino il limite dei 100 metri utilizzando degli Estensori Ethernet. Questi consentono di raggiungere distanze fino a 3 chilometri su doppino telefonico Cat 5, 6 o 7.

Schema Estensore Ethernet eX-1S1110-XT
Estendete quattro porte 10/100/1000 Ethernet su doppino telefonico o cavo coassiale

Estendete quattro porte Ethernet fino a 3 chilometri su doppino telefonico Cat 5, 6 o 7.

Schema Estensore Ethernet eX-4S1110-XT
Su
  • Prodotti
  • Applicazioni
  • Su Perle
  • Contattaci
  • Come Acquistare
  • Supporto tecnico
  • Mappa del Sito
  • Note legali
  • Privacy e Cookie

Prodotti di Perle

specialix Chase Research
© 1996 - Perle. Tutti i diritti riservati.
×

Inviaci un'e-mail

Hai domande?

Possiamo fornire ulteriori informazioni sui nostri prodotti oppure prepararti un preventivo


icona di posta elettronicaInvia un'e-mail
contattaci-iconInvia un'e-mail callo-iconaChiamaci